Overview
One model from the ELENA extraction to the annihilation vertex, in the CST coordinate frame.
System
Rebuild model
Regenerates the per-coil and per-electrode field maps and PenningTrap_CST.g4bl. Point it at your CST electrostatic exports to replace the Laplace stand-in basis.
Storage
Recent runs
Beam
Antiprotons handed over from the ELENA → LNE02 Xsuite line at the AEgIS delivery point.
Save the tracked particles at LNE02$END from your Xsuite script, then point to the file:
import numpy as np
p = particles # xp.Particles at lne02$end
np.savez("lne02_end.npz", x=p.x, px=p.px, y=p.y, py=p.py,
zeta=p.zeta, delta=p.delta, p0c=p.p0c, state=p.state)
Phase space
Magnets
23 superconducting and corrector coils. CST magnetostatic ROM, B = Σ Iₖ·bₖ.
Electrodes
66 trap electrodes. Electrostatic ROM, Φ = Σ Vᵢ·φᵢ.
Simulate
Track the beam through the tuned fields with G4beamline.
Custom Geant4 11.4 application (hbar_g4/): one e⁺ per event from the positron line through the real fields into the silica, Geant4 stopping → positronium (7 %, 142 ns o-Ps decay to 3γ) → 205+1693 nm laser → Rydberg Ps (motional-Stark limit in the local B) → charge exchange in the p̄ cloud taken from a G4beamline run → H̄ (falls under gravity) → gratings and detector, where it annihilates into a p̄ + e⁺ that Geant4 annihilates (π, γ). Rare steps use weights; results are per shot of 2×10⁶ e⁺.
AEgIS 2023 ballistic sequence (Volponi 2024, §4.2.4): P12 → A1 parabola, P11 wall, A0 reflector, Ps target in, degrader out. The p̄ cloud is launched from P12; G4beamline records every p̄ at the formation time.
Scenario
Degrader & catching
This run
Queue
Positrons
From the ²²Na source to the bunch: Geant4 through the capsule and the solid-neon moderator, then the slow beam, the buffer-gas trap and the accumulator.
1 · Source + moderator (G4beamline)
²²Na (β⁺ 90.3 %, 546.44 keV endpoint) on a Ta backing behind a 5 µm Ti window (iThemba capsule), solid neon on a Cu cone at 7 K, 120 G guide field. Geant4 tracks every β⁺ until it stops; re-emission from the neon is a diffusion-escape model (Geant4 has no moderation physics).
2 · Chain settings
3 · Full positron line in Geant4
Custom Geant4 11.4 app (hbar_g4/positron_line.cc): the same source and moderator, then re-emission from the neon surface, guide fields 120 → 250 → 750 G, moderator bias and slow-e⁺ filter, and the 3-stage N₂ buffer-gas trap with an e⁺–N₂ process (a¹Π excitation, Ps formation; Marler & Surko 2005). Every positron is tracked from the source until it is trapped, lost or escapes.
Geant4 positron line: source → trap
Positrons per second, stage by stage
Where the β⁺ stop (Geant4)
Moderated beam and trapping
Accumulator
Results
Annihilation vertices, detector response and energy deposition.
Runs
Click to open, ⌘/Ctrl-click to compare.
Geant4 positronium → H̄
Ballistic transfer
Annihilations along the trap
Vertex map (r–z)
Transverse (x–y)
By electrode
Scintillator events
Run parameters
Physics
Fields and where the p̄ stop
Annihilation profile with the run's on-axis Bz and electrostatic potential.
Fate of every antiproton
p̄ after the degrader
Annihilation products: energy spectra
Kinetic energy at creation of the direct annihilation products, per annihilation.
Charged-pion multiplicity
Pion polar angle
Pion azimuth φ
Scintillator time-of-flight map
Detector coincidences
Annihilation time
Energy deposit per hit
Particle census
Surrogate
Instant predictions of the G4beamline outcome from a Gaussian-process model trained on sampled runs.
New surrogate
Baseline = your current Magnets, Electrodes and Simulate (degrader & catching) settings. Only the knobs vary.
Surrogates
Live prediction
outside training rangeUses your current settings and updates as you move sliders on the Magnets, Electrodes and Simulate pages.